e-VF Electronic Von Frey

Model
38450
The UB Electronic Von Frey of original design, for automatic assessment of Hypersensitivity and Allodynia in rats and mice, automatically records the animal response to user-controlled application...
Quantity
-
+
没有此类产品
Overview
Key Benefits
Citations
The UB Electronic Von Frey of original design, for automatic assessment of Hypersensitivity and Allodynia in rats and mice, automatically records the animal response to user-controlled application of force rate.
 
A touch stimulator transducer is mounted on a Perspex handle, so that routine procedures may be employed to examine and test the animal skin sensitivity. A prism of original design is of great help to localize the aimed stimulation area
 
The completion of each test may be indicated either by the sudden release of the paw or by pressing the external foot-pedal. The display then gives the operator a summary of the results of the test (i.e. force and time corresponding to the animal response).
 
The rate of application of the force is set by the operator and the e-VF includes software tools that help the operator in consistently applying the force at the desired rate.
 
The device includes as standard both a control unit with internal memory and the NEW DCA software for signal monitoring, data transfer and analysis. The results of several hundred tests may be stored in the e-VF, be browsed on the control unit and/or trasferred to a PC in proprietary, Excel (.xls) or text (.txt) format, to be managed by most statistical analysis packages available on the market.
 
The instrument includes:
an electronic unit
a touch stimulator with a viewing prism of original design
the software
 
The 37450-278 Base assembly for plantar stimulation, or with the self-supporting perforated platforms 37450-045 / 37450-085 (see picture), can be purchased separately to complete the set-up, when the stimulation target is the rodent plantar surface. 
 
 
Corresponding parameter set not found, please add it in property template of background
  • Resolution: 0.1g
  • Maximum Applicable Force: 1000g
  • User-controlled application of force rate
  • Speaking about force, although the sensor can detect forces from 0 to 1000g, it is reasonable to set the device lower limit to 5g, given by difficulty, even for the most skilled user, to apply forces below this threshold.
  • DCA Software included - NEW 2014 Release
  • Location of the target via the original prism-design
  • Automatic recording of animal response
暂未实现,敬请期待
暂未实现,敬请期待
Previous article
Next article

Related Products

I want to make an inquiry
Custom buttons
Key words
I want to make an inquiry
Custom buttons
Key words
I want to make an inquiry
Custom buttons
Key words
I want to make an inquiry
Custom buttons
Key words
I want to make an inquiry
Custom buttons
Key words
I want to make an inquiry
Custom buttons
Key words
I want to make an inquiry
Custom buttons
Key words
I want to make an inquiry
Custom buttons
Key words